Professional Differential probes DC-25Mhz ADP25 Max Voltage 1300V 3ATTENUATOR r

$ 127.21

Availability: 500 in stock
  • Restocking Fee: No
  • All returns accepted: Returns Accepted
  • Condition: New
  • Item must be returned within: 30 Days
  • Refund will be given as: Money Back
  • Model: DP25
  • MPN: DP25
  • Brand: Aidetek
  • Return shipping will be paid by: Buyer
  • Country/Region of Manufacture: Taiwan

    Description

    Professional Differential probes DC-25Mhz ADP25 Max Voltage 1300V 3ATTENUATOR r
    Description
    New Professional
    Differential
    probes DC-25Mhz  ADP25 Max Voltage 1300V or 1000V RMS
    Brand new with 14 days return policy, one year warranty
    3 RANGE ATTENUATOR.
    1000V INPUT CAT III
    LOW BATT. AUTO OFF.
    SEPARATING DESIGN.CONVENIENT, DURABLE.
    MEET CE, IEC 1010, EN 61010, UL 3111.
    Band width (-3dB, 50Ω
    load):
    DC-25MHz . ( x 20: DC~15MHz)
    Accuracy :
    ± 2% at 20-30℃ 70% RH after 20 minutes warm up.
    Attenuation :
    x 20, x 50, x 200 ( Into 1MΩ scope ) ; x 40, x 10
    , x 400 ( Into 50Ω load )
    Maximum operation Voltage ( DC + peak AC ) :
    ≦ ± 140V at x 20
    ≦ ± 350V at x 50
    ≦ ± 1300V at x 200
    Maximum input Differential Voltage :
    1300V ( DC + peak AC ) or 1000V RMS
    Maximum input Voltage to Ground :
    1000V ( DC + peak AC ) or 600V RMS
    Common Mode Rejection Ratio ( CMRR ):
    60Hz :
    >10,000 : 1
    100Hz:
    >1,000 : 1
    1MHz:
    > 300 : 1
    Noise :
    ≦ 2 mV rms ( Into 50Ω load )
    Input Impedance :
    2MΩ, 2.3 PF between inputs and ground.
    4MΩ, 1.2 PF between inputs.
    Power :
    external 6V-9V DC
    .
    WARNING
    Do not use DP-25 above 1000v ( DC + peak AC ) between ground and the input or 1,300V ( DC + peak AC ) between the input lead.
    Do not operate DP-25 in wet or damp condition.
    Do not operate DP-25 in an explosive atmosphere.
    Do not immerse DP-25 in liquids.
    Do not operated DP-25 without covers.
    Please change the battery when the "LOW BATT " LED is lighted. At this time DP-25 can operate but not guaranteed the accuracy.
    DP-25 can not operate if both POWER and LOW BATT LED are not light.
    FEATURES
    The DP-25 FET input differential probe provieds a safe means of measuring circuits with floating potentials up to 1000 V ( DC+ peak AC ) from ground and 1300V ( DC + peak AC ) differential.
    The DP-25 converts the high voltage differencial input signal to a low voltage ground refereced signal for display on any Oscilloscope.
    The output BNC of DP-25 is calibrted to drive a high impedance ( 1M
    Ω
    ) load.
    INSTRUCTION FOR USE
    Connect the output BNC of DP-25 to the input BNC of the Oscilloscope by the accessory BNC cable.
    Adjust the vertical offset of the Oscilloscope if necessary.
    Set the select proper range of the DP-25 and the V / DIV of the Oscilloscope according to the scale conversion chart.
    Scale conversion chart : The effective V / DIV is the attenuation factor of x 20, x 50, x 200 multiplied by the scale factor of the Oscilloscope. It will be twice when the 50
    Ω
    load was used. For example, with the range set at x 200,
    and the scope set to 0.5 V / DIV, the effective V / DIV equals 200 x 0.5 or 100 V, with the 50
    Ω
    load was used, it becomes 200V, the power consumption will increase too.
    NOTE :
    If the voltage of the input signal exceeeds the linear range of the setting range.The signal output of the DP-25 would not accurately, the wave form display will be cut off.
    Shipping ALL orders will ship from our China warehouse by air mail with track number, it takes around 7-12 business days to arrive, the track number will e-mail to you, contact us at
    [email protected]
    if you want fast shipping, you can pay extra - for fast shipment, thank you
    This is manual:
    http://www.aidetek.com/New_products_info/Datasheet/Pintek/A
    DP25
    _Manual.pdf
    eBay Cross Border Trade powered by Channel Effect