-40%
Fluke Calibration 5609-12-D Secondary Reference PRT Probe, 5-Pin DIN
$ 763.59
- Description
- Size Guide
Description
Subscribe to Our NewsletterFluke Calibration 5609-12-D Secondary Reference PRT Probe with 5-Pin DIN for Tweener Thermometers, 12 in. x 1/4 in., -200 °C to 670 °C, 6 ft. Lead
Brand:
Fluke Calibration
Model No:
5609-12-D
Ref No:
3056578
Our Model No:
560912D
Product Overview
Features
Termination: 5-pin DIN for Tweener Thermometers
Temperature range: -200 °C to 670 °C
Nominal resistance at 0.01 °C: 100 Ohm ± 0.5 Ohm
Temperature coefficient: 0.0039250 Ohm/Ohm/°C
Relative Accuracy ( Includes short-term repeatability and 100 hr drift; calibration will add additional uncertainties): ±0.007 °C at -200 °C; ±0.008 °C at 0 °C; ±0.020 °C at 420 °C; ±0.027 °C at 660 °C
Short-term repeatability (Three thermal cycles from min to max temp, includes hysteresis, 95% confidence (k=2)): ±0.007 °C at 0.010 °C; ±0.013 °C at max temp
Drift (After 100 hours at max temp, 95 % confidence (k=2)): ±0.01 °C at 0.010 °C; ±0.02 °C at max temp
Hysteresis: ±0.01 °C maximum
Sensor length: 30 mm ± 5 mm (1.2 in. ± 0.2 in.)
Sensor location: 3 mm ± 1 mm from tip (0.1 in. ± 0.1 in.)
Sheath material: Inconel 600
Minimum insulation resistance: 500 MOhm at 23 °C, 10 MOhm at 670 °C
Transition junction temperature range (Temperatures outside this range will cause irreparable damage; for best performance, transition junction should not be too hot to touch): -50 ºC to 200 °C
Transition junction dimensions: 71 mm x 12.5 mm (2.8 in. x 0.49 in.)
Minimum immersion length (Per ASTM E 644) (<5 mK error): 100 mm (3.9 in)
Maximum immersion length: 305 mm (12 in)
Response time (Per ASTM E 644): 12 seconds typical
Self heating (in 0 °C bath): 50 mW/°C
Lead-wire cable type: PTFE 24 AWG
Lead-wire length: 1.8 m (6 ft)
Lead-wire temperature range: -50 °C to 250 °C
Size: 12 i.n x 1/8 in.
Description
The Fluke Calibration 560912D Secondary Reference PRT Probe with 5-Pin DIN for Tweener Thermometers, 12 in. x 1/4 in., -200 °C to 670 °C, 6 ft. Lead is a very stable thermometer from -200 °C to 670 °C. Its short-term stability at the triple point of water is only ± 7 mK and its one-quarter inch (6.23mm) diameter lets you get accurate measurements in only 100 mm of immersion.
When looking for improved response time and reduced stem effect in shallow immersion, look for small diameter probes, because the measurement error (called "stem effect") is caused by the diameter of the stem rather than the length of the stem.
The Fluke Calibration 5609-15-D has an Inconel sheath and is made using a special manufacturing process, giving it great precision over a wide temperature range. The sensors for this probes is reference-grade platinum and features four-wire connections with less noisy measurements than two-wire counterparts.
Included Components
1 - Coefficient Sheet
1 - User Manual CD
Terms & Conditions
Please note estimated delivery time above. Contact us for details or if you have a delivery requirement. We ask for your patience while striving to ensure your shipment arrives quickly and accurately.
Domestic Shipping
FREE Standard Shipping on items OVER and less than 30lbs to continental U.S. Add for AK, HI, or PR. Please contact us for shipping rates to any overseas US territories including: Northern Mariana Islands, Guam, Puerto Rico, U.S. Virgin Islands and American Samoa.
PO Boxes/APOs require USPS shipping and may therefore experience longer lead times
6.25% Sales Tax for shipping to MA
International Shipping
Due to international voltage requirements, please ask us prior to purchasing to confirm your product will operate correctly in your country.
Please contact us for shipping rates to any overseas U.S. territories.
International customers are responsible for all shipping charges, including any duties or taxes.